GWINNETT PROPERTY INSPECTIONS
EIFS - Exterior Insulation and Finishing Systems
Because EIFS (Exterior Insulated Finish Systems) rely on a perfect seal
at the exterior surfaces, they are susceptible to entrapment of moisture
inside the system. Water can enter the system where seams and seals
fail, where moisture migrates from inside the building and where punched
openings (windows, doors, etc.) are present. Because of the low vapor
permeability of the finish, water trapped behind the EIFS cannot dry out
quickly toward the outside of the wall (see figure 1). Depending
on the rest of the wall system design and installation, there may also
be limited drying potential to the inside. Limited drying potential in
combination with high leakage potential can lead to moisture buildup
inside the wall, and eventually to mold growth and structural decay.
|
What Is EIFS (Exterior Insulated Finish
Systems)? |
|
While giving
the appearance of stucco, EIFS is actually a multi-layered wall
system that consists of the following components:
 |
Insulation Board
- Made of polystyrene (or similar material), which is
secured to the exterior wall surface.
|
 |
Base Coat
- Applied on top of the insulation and reinforced with fiber
mesh. |
 |
Finish Coat
- Applied on top of the base coat giving a durable,
crack-resistant finish.
|
The first half
of the acronym, "Exterior Insulation" is derived from the fact
that the first component installed is a foam insulation board.
The foam board is mechanically and/or adhesively attached to the
exterior sheathing of the home. In this respect the foam board
serves as an exterior insulating layer. Over this foam board is
applied a synthetic base-coat material in which is embedded a
fiberglass reinforcing mesh. This is typically referred to as
the "base-coat". On top of the base coat is applied one or more
"finish coats". This is the exterior layer that gives the
product its stucco-like appearance. Hence the second part of the
acronym "Finish Systems".
EFIS
provides many advantages that other exterior finishes and
sidings do not. Chief among these are superior energy
efficiency and great design flexibility. As a matter
of fact, studies have shown that EIFS can reduce the air
infiltration in a wall by as much as 55%, when compared to
standard brick or wood construction. One should bear in mind
that an EIFS system is a non-structural component of the wall.
In other words, it is not designed to be weight bearing.
Most early
EIFS employed a
face seal
approach to rainwater management, and was thus very susceptible to
failure. Because of these early problems, most EIFS now
incorporates some sort of a drainage plane to allow for moisture
drainage. Newer installations incorporating this design could
be considered
concealed
barrier
systems.
However, due to the nature of the product and the realities of
the construction process, even newer drainage EIFS systems can
experience problems:
 |
“Short-cuts” are often taken in the application of EIFS
systems, causing the primary face seal moisture barrier to
fail and leak (lack of proper caulking, flashing, etc.).
|
 |
The
integrity of the second line of defense is highly dependent
on correct detailing by the designer and proper installation
by the builder and his subcontractors. Very often,
flashings, housewrap, windows, doors, etc., are improperly
installed. |
 |
EIFS does
not breathe and will not allow trapped moisture to evaporate
easily, which can cause great damage over time.
|
|
|
The Causes Of Most EIFS Problems |
|
Since EIFS
clearly provides many advantages, what's the big deal? The
basic problem begins with the erroneous belief that homes can be
made to be “water proof”. The simple truth is, they cannot.
For example, even when applied by professional caulking
applicators, All caulk joints will eventually
fail. . . .even those caulk joints made under laboratory
conditions. No residential windows are fully
waterproof. . . .they are designed and manufactured to a
water-resistant standard. Some water will always find a way
in. When it can't get out, you have a problem.
A.
Why Can EIFS Be A Problem?
Homes clad with EIFS (Exterior Insulation and Finish
Systems) a.k.a. synthetic stucco have a very strong
tendency to retain moisture between the sheathing of the home
and the finish system. The design of EIFS, unlike other systems
(brick, stone, siding, etc.), does not allow the moisture to
drain out. The problem is water intrusion and entrapment in the
wall cavities. The moisture can sit in contact with the
sheathing for a prolonged period and rotting may result. Damage
can be serious.
While a brick or stone wall will contain an internal
drainage plane behind it and weep holes along the bottom edge to
allow for water drainage, moisture intruding into the EIFS wall
cavities is more damaging because it cannot readily escape back
out through the waterproof EIFS exterior as quickly as it can
through brick veneer, stone, or cement stucco, leaving the
internal sheathing and wood framing vulnerable to rot and decay.
Successful
installation of EIFS depends upon keeping water out of the wall
cavities. Consequently, in an effort to keep the water out, an
industry-wide installation standard was developed that details
installation procedures to be followed. In conjunction with
this, the EIFS manufacturers then trained and certified
applicators to install their products and supplied them with
materials which met specification standards.
But, here is
where the system begins to break down, because unfortunately,
the manufacturers failed to take into account the realities of
residential construction:
 |
Barrier type systems rarely work.
The EIFS external barrier system depends upon a perfect
external water barrier to keep water out of wall cavities.
Since the outer shell is the only barrier against water
intrusion, it must form a “perfect” barrier at
“all times.” When there are so many entry points for
water intrusion in the exterior shell of a house, this is an
unrealistic expectation.
|
 |
Lack of inspection and enforcement of standards. Most manufacturers, unrealistically expected that the
building industry on its own (including public inspection
departments), would maintain industry standards &
specifications, provide oversight, and provide inspection of
the EIF system as it was installed. Everyone thought that
someone else was minding the store, consequently, the vast
majority of EIFS applications nation-wide, have never been
inspected. Compounding this problem is the fact that the
EIFS manufacturers have failed to insist upon the very
standards they helped originate, be met by the applicators
they supply materials to. |
 |
Evolution of application guidelines.
Another consideration is that guidelines for EIFS
installation have been evolving over the years. An example
of this is below grade termination of the EIFS. While not
allowed by building code, early on, it was allowed by some
manufacturers specifications. However, due to problems with
this type of application nation-wide, in 1996 Dryvit Corp
(one of the largest EIFS manufacturers), changed all of its
specifications to require an 8 inch separation be left
between the EIFS and soil (termite problems in the South &
carpenter ants in the North, moisture wicking up into the
EIFS, frost damage, inability of the EIFS to drain water
away if it is buried, etc.). Unfortunately, this type of
new information has been slow to “trickle down”
through the information
chain (from the manufacturer
č distributor
č applicator). Some distributors even claim their insulation-board
doesn’t wick water, and consequently can be placed below
grade (experience shows that it does, however). |
 |
Leaks and damage are hidden from view.
There are few, if any, external visual clues to an early
leakage problem. As a matter of fact, it can take years for
an intermittent leak to evidence itself as damaged
sheathing, window leaks, rotted framing, mold growth, etc.
Many insurance companies, builders, and applicators may not
take a leakage problem seriously, until they can actually
see the damage. The reason for this “mind-set”
is understandable, because no one wants to be responsible to
pay for repairs that may be unnecessary. Unfortunately, by
waiting until a problem is noticeable as visible damage, the
word repair can become the word replace. What was once a
relatively inexpensive repair has become a very expensive
replacement. |
|
|  | 
 

  


|